PEER REVIEWED JOURNAL
PAPERS
-
Z. Ider, N. G. Gencer, E. Atalar, and H. Tosun, Electrical
Impedance Tomography of translationally uniform cylindrical objects
with general cross sectional boundaries, in IEEE Trans. on
Medical Imaging, Vol: MI9, No:1, pp. 49-59, March 1990.
-
E.
Atalar, and L. Onural, A respiratory motion artifact reduction
method in magnetic resonance imaging of chest, in IEEE Trans. on
Medical Imaging, Vol: MI10, No:1, pp.11--24, March 1991.
-
E.
R. McVeigh and E. Atalar, Cardiac tagging with breath-hold CINE
MRI, Magnetic Resonance in Medicine, Vol:28, No:2, pp.318-327,
December
1992.
-
E.
Atalar and E. R. McVeigh, Optimization of tag thickness for
measuring position with magnetic resonance imaging, in IEEE
Trans. on Medical
Imaging, Vol: 13, No:1,pp.152-160, March 1994.
-
E. Atalar and E. R. McVeigh, Minimization of dead-periods in MRI
pulse sequences for imaging oblique planes, Magnetic Resonance
in Medicine, Vol:32, No:6, pp.773-777, December 1994.
-
R. M. Judd, S. B. Reeder, E. Atalar, E. R. McVeigh, E. A.. Zerhouni,
A magnetization-driven gradient echo pulse sequence for the study
of myocardial perfusion. Magnetic Resonance in Medicine, Vol:
34, No:2, pp.276-282, Aug 1995.
-
J. A. Lima, R. M. Judd, A. Bazille, S. P. Schulman, E. Atalar, and
E. A. Zerhouni, Regional heterogeneity of myocardial perfusion
within human myocardial infarcts demonstrated by contrast enhanced
ultrafast MR, Circulation, Vol: 92, No:5, pp.1117-1125, Sep
1995.
-
P. A. Bottomley, E. Atalar, and R. G. Weiss, Human Cardiac
High-Energy Phosphate Metabolite Concentrations by 1D-Resolved NMR
-
Spectroscopy, Magnetic Resonance in Medicine, Vol: 35, No: 5. pp.
664-670, May, 1996.
-
E. Atalar, P. A. Bottomley, O. Ocali, L. C. Correia, M. D. Kelemen,
J. A. C. Lima and E. A. Zerhouni, High Resolution Intravascular MRI
and MRS using a Catheter Receiver Coil, Magnetic Resonance in
Medicine, Vol: 36, No: 4. pp. 596-605, October, 1996.
-
O. Ocali, and E. Atalar, Intravascular Magnetic Resonance Imaging
Using a Loopless Catheter Antenna. Magnetic Resonance in
Medicine, 1997. 37(1): p. 112-118.
-
S.
B. Reeder, E. Atalar, B. B. Bolster, E. R. McVeigh Quantification
and Reduction of Ghosting Artifacts in Echo Planar Imaging, Magnet
Resonance in Medicine, 38(3):429-439, 1997.
-
C. D. Constantinides, E. Atalar, and E. R. McVeigh,
Signal-to-Noise Measurement in Magnitude Imaging from NMR Phased
Arrays. Magnetic Resonance in Medicine, 38(5): 852-857,
1997.
-
D. A. Bluemke, J. L. Boxerman, E. Atalar, E. R. McVeigh, Segmented
K-space cine breath-hold cardiovascular MR imaging: Part 1.
Principles and technique, Am. J. Radiol. 1997, 169:395-400.
-
L.
C. L. Correia, E. Atalar, M. D. Kelemen, O. Ocali, G. M. Hutchins,
J. L. Flag, G. Gerstenblith, E. A. Zerhouni, and J. A. C. Lima,
“Intravascular magnetic resonance imaging of aortic atherosclerotic
plaque composition,” Arteriosclerosis Thrombosis and Vascular
Biology, vol. 17, pp. 3626-3632, 1997.
-
O. Ocali, and E. Atalar, Ultimate Intrinsic Signal-to-Noise Ratio
in MRI. Magnetic Resonance in Medicine, vol. 39, pp. 462-473,
1998.
-
P. Croisille, M. A. Guttman, E. Atalar, E. R. McVeigh, E. A.
Zerhouni, Precision of Myocardial Contour Estimation with Tagged
MR Images Using a Novel “Black Blood” Technique. Academic
Radiology, 5(2): 93-100, 1998.
-
J. L. Boxerman, Elliot R. McVeigh, E. Atalar, J. A. C. Lima, D. A.
Bluemke, Advanced MRI Techniques for the Evaluation of the Heart and
Great Vessels, Radiographics, vol. 18, pp. 543-564, 1998.
-
B. D. Bolster, E. Atalar, C. Hardy, E. R. McVeigh, Accuracy of
Pulsewave Velocity Measurement using 1-D Magnetic Resonance Imaging,
Journal of Magnetic Resonance Imaging, 8:878, 1998.
-
E. Atalar, D. L. Kraitchman, J. Lesho, B. Carkhuff, O. Ocali, M.
Solaiyappan, M. A. Guttman, Catheter-tracking FOV MR Fluoroscopy,
Magnetic Resonance in Medicine, 40:865-872, 1998.
-
X. Yang, B. D. Bolster, D. L. Kraitchman, E. Atalar, Intravascular
Magnetic Resonance-Monitored Balloon Angioplasty: A feasibility
Study on Rabbit Models, JVIR, 9:953-959, 1998.
-
S. B. Reeder, E. Atalar, A. Z. Faranesh, E. R. McVeigh,
Referenceless Interleaved Echo Planar Imaging, Magnetic Resonance in
Medicine, 41: (1) 87-94 1999.
-
S. B. Reeder, E. Atalar, A. Z. Faranesh, E. R. McVeigh,
Multi-echo
segmented k-space imaging: An optimized hybrid
sequence for ultrafast cardiac imaging. Magnetic
Resonance in Medicine, 41(2) 375-385 1999.
-
D. Artemov, G. Revelon, E. Atalar, D. A. Bluemke, Z. M. Bhujwalla,
Switchable Multicoil Array for MR Microimaging of Breast Lesions,
Magnetic Resonance in Medicine, 41(3):569-574, 1999.
-
K. A. Shunk, J. A. C. Lima, A. W. Heldman, E. Atalar,
Transesophageal Magnetic Resonance Imaging, Magnetic Resonance in
Medicine, 41(4):722-726, 1999.
-
B. D. Bolster, E. Atalar, Minimizing Dead-Period in Flow-Encoded or
–Compensated Pulse Sequences while Imaging in Oblique Planes. J.
Magnetic Resonance Imaging, 10(2):183-1922, 1999.
-
S. B. Reeder, A. Z. Faranesh, E. Atalar, E. R. McVeigh,
A Novel
Object-Independent “Balanced” Reference Scan for Echo Planar Imaging,
Journal of Magnetic Resonance Imaging, 9(6):847-852, 1999.
-
X. Yang, E. Atalar, E.A. Zerhouni, Intravascular MR Imaging and
Intravascular MR-Guided Inteventions, International Journal of
Cardiovascular Interventions, 2:85-96, 1999.
-
X. Yang, E. Atalar, Intravascular MR-guided Angioplasty Using An
MR Imaging-Guidewire: A Feasibility Study". Radiology, 217(2):501-506,
2000.
-
J.
M. Serfaty, E. Atalar, J. Declerck, P. Karmakar, H.H. Quick, K.
Shunk, A. Heldman, X. Yang, Real-time Projection MR Angiography:
Feasibility Study. Radiology 217:290-295, 2000.
-
C. Yeung, E. Atalar, RF Transmit Power Limit for the Barewire
Loopless Catheter Antenna, J. Magnetic Resonance Imaging, Journal of
Magnetic Resonance Imaging, 12:86-91, 2000.
-
J. M. Serfaty, X. Yang, P. Aksit, H. H. Quick, M. Solaiyappan, E.
Atalar, Toward Coronary Interventions. Invited. Journal of
Magnetic Resonance Imaging, 12(4):590-594, 2000
-
H. H. Quick, J. M. Serfaty, H. Pannu, R. Genadry, C. Yeung, E.
Atalar, Endourethral MRI, Magnetic Resonance in Medicine, 45:138-146,
2001.
-
B. D. Bolster, J. M. Serfaty, E. Atalar, In-vivo Measurement of
Pulsewave Velocity in Small Vessels using Intravascular MRI,
Magnetic Resonance in Medicine, 45:53-60, 2001.
-
C.
Yeung, E. Atalar, A Green's Function Approach to Local RF Heating in
Interventional MRI, Medical Physics 28(5) 826-832, 2001.
-
K. A.Shunk, E. Atalar, J. Garot, J. A. C. Lima Transesophageal
Magnetic Resonance Imaging of Patients with Aortic Atherosclerosis,
J. Am. Coll. Cardiol. Jun 15; 37(8):2031-5, 2001.
-
N. F. Osman, S. Sampath, E. Atalar, and J. L. Prince "Imaging
Longitudinal Cardiac Strain on Short Axis Images Using
Strain-Encoded (SENC) MRI," MRM, 46:324-334, 2001.
-
P. A. Bottomley, E. Atalar, R. F. Lee, K. A. Shunk, A. Lardo,
Cardiovascular MRI probes for the outside in and for the inside out,
Magnetic Resonance Materials in Physics, Biology and Medicine MAGMA
11(1-2):49 - 51, 2000
-
X. Yang, E. Atalar, D. Li, J. M. Serfaty, D. Wang; A. Kumar, L.
Cheng, Magnetic Resonance Imaging Permits In Vivo Monitoring of
Catheter-Based Vascular Gene Delivery, Circulation 104:1588-1590
2001.
-
K.
A.Shunk, E. Atalar, J. A. C. Lima. Possibilities of transesophageal MRI for assessment of aortic
disease: a review. Int J Card Imaging 17(3):179-85, 2001.
-
P.
Aksit, A. Derbyshire, J. M. Serfaty, E. Atalar, Multiple field of
view MR fluoroscopy, Magnetic Resonance in Medicine, 47(1):53-60,
2002.
-
Christopher
J. Yeung, Robert C. Susil, and Ergin Atalar, RF Safety of Wires in
Interventional MRI: Using a Safety Index, Magnetic Resonance in
Medicine 47(1):187-193, 2002.
-
R. C. Susil, C. J. Yeung, H. R. Halperin, A. C. Lardo, E. Atalar,
Multifunctional Interventional Devices for MRI: A Combined
Electrophysiology / MR Imaging Catheter, MRM 47(3):594-600,
2002
-
Fichtinger, G., A. Krieger, R.C. Susil, A. Tanacs, L.L. Whitcomb,
and E. Atalar, Transrectal prostate biopsy inside closed MRI
scanner with remote actuation, under real-time image guidance,
in Medical Image Computing and Computer-Assisted Intervention-Miccai
2002, Pt 1. 2002. p. 91-98.
-
Smita Sampath, J. Andrew Derbyshire, Nael F. Osman Ergin Atalar, and
Jerry L. Prince Real-Time Imaging of Two-dimensional Cardiac Strain
Using a FastHARP Pulse Sequence, Magn Reson Med 2003;50(1):154-163.
-
C. J. Yeung, R. C. Susil, E. Atalar, RF Heating due to Conductive
Wires During MRI Depends on the Phase Distribution of the Transmit
Field, Magnetic Resonance in Medicine 48:1096–1098, 2002
-
X. Yang, C. J. Yeung, H. Ji, J. M. Serfaty, E. Atalar, Thermal
effect of intravascular MR imaging using an MR imaging-guidewire: an
in vivo laboratory and histopathological evaluation, Med. Sci. Monit.
8(7) 2002.
-
B. Qui, C. J. Yeung, X. Du, E. Atalar, X. Yang, Development of an
Intravascular Heating Source Using An MR Imaging-Guidewire: Toward
Thermal Enhancement of Endovascular Gene Transfection, Journal of
Magnetic Resonance Imaging 16:716–720, 2002
-
A.
Yung, Y. Oner, J. M. Serfaty, M. Feleney, X. Yang, E. Atalar, Phased
array MRI of canine prostate using endorectal and endourethral
coils, Magnetic Resonance in Medicine, 49(4) 710-715, 2003.
-
Kraitchman DL, Heldman AW, Atalar E, Amado LC, Martin BJ, Pittenger
MF, Hare JM, Bulte JW. In vivo magnetic resonance imaging of
mesenchymal stem cells in myocardial infarction. Circulation
2003;107(18):2290-2293.
-
Susil RC, Krieger A, Derbyshire JA, Tanacs A, Whitcomb LL,
Fichtinger G, Atalar E. System for MR image-guided prostate
interventions: canine study. Radiology 2003;228(3):886-894.
-
J. M. Serfaty, X. Yang, T. Foo, A. Kumar, A. Derbyshire, E. Atalar,
MRI-guided coronary catheterization and PTCA: A feasibility study on
a dog model. Magn Reson Med 2003;49(2):258-263.
-
Susil
RC, Yeung CJ, Atalar E, "Intravascular extended sensitivity (IVES)
MR imaging antennas." Magnetic Resonance in Medicine, 2003; 50(2):
383-390.
-
Karmarkar P, Kraitchman DL, Izbudak I, Hoffman LV, Amado LC,
Fritzgel D, Young R, Pittenger MF, Bulte JW, Atalar E. MR-Trackable
Intramyocardial Injection Catheter. Magn Reson Med 2004; 51(6):
1163-1172.
-
Tsekos N. V., Atalar E., Li D, Omary R A, Serfaty J M,
Woodard P. K., Magnetic Resonance Imaging-Guided Coronary
Interventions, Invited, J. Magnetic Resonance Imaging, 2004
19(6): 734-749.
-
Susil RC, Camphausen K, Choyke P, McVeigh ER, Gustafson GS, Ning H,
Miller RW, Atalar E, Coleman CN, Menard C, A System for Prostate
Brachytherapy and Biopsy in a Standard 1.5 T MRI Scanner, Magnetic
Resonance in Medicine, 52:683-687, 2004.
-
Celik
H, Eryaman Y, Altintas A, Hafez IA, Atalar E. Evaluation of Internal
MRI Coils using Ultimate Intrinsic SNR. Magn Reson Med 52:640-649,
2004.
-
Paliwal
V, El-Sharkawy AM, Du X, Yang X, Atalar E, SSFP Based MR
Thermometry, Magnetic Resonance in Medicine, 52:704-708, 2004.
-
Krieger
A, Susil RC, Menard C, Coleman JA, Fichtinger G, Atalar E, Whitcomb
LL. Design of A Novel MRI Compatible Manipulator for Image Guided
Prostate Intervention, IEEE Trans. BME, 52(2) 306-313 2004.
-
Arepally A, Karmarkar P, Weiss C, Rodriguez ER, Lederman RJ, Atalar
E, Magnetic Resonance Image-Guided Transseptal Puncture in a Swine
Heart, J. Magnetic Resonance Imaging, (4): 463-467 Apr 2005.
-
Ménard, C., Susil, R.C., Choyke, P., Coleman, J., Grubb, R., Gharib,
A., Krieger, A., Guion, P., Thomasson, D., Ullman, K., Gupta, S.,
Espina, V., Liotta, L., Petricoin, E., Whitcomb, L.L., Fitchtinger,
G., Atalar, E., Coleman, N.C., Camphausen, K. An Interventional MRI
Technique for the Molecular Characterization of Intra-Prostatic
Dynamic Contrast Enhancement In Press, Molecular Imaging Vol. 4,
No:1, pp. 63-66, 2005 (Cover).
-
Raman
VK, Karmarkar PV, Guttman MA, Dick AJ, Peters DC, Ozturk C, Pessanha
PSS, Thompson RB, Raval AN, DeSilva R, Aviles RJ, Atalar E, McVeigh
ER, Lederman RJ, Real-Time Magnetic Resonance-Guided Endovascular
Repair of Experimental Abdominal Aortic Aneurysm in Swine, Journal
of the American College of Cardiology, Vol. 54, No. 12, pp. 2069-77,
2005.
-
B.
Qui, El-Sharkawy AM, Atalar E., V. Paliwal, F. Gao, P. Karmarkar, X.
Yang, Simultaneous RF Heating and MR Thermal Mapping Using An
Intravascular MR-Imaging/RF-Heating System, Magnetic Resonance in
Medicine, Vol. 54, 226-230, 2005.
-
B. Qiu, P. Karmarkar, C. Brushett, F. Gao, R. Kon, S. Kar, E.
Atalar, X. Yang. Development of An 0.014-Inch
Magnetic Resonance Imaging-Guidewire, Magnetic Resonance in
Medicine, Vol 53, 986-990, 2005.
-
E.
Atalar, Safety of Interventional MRI Devices, Invited,
Academic Radiology, Vol 12, 9: 1149-1157, 2005.
-
A.
N. Raval, P. V. Karmarkar, M. A. Guttman, C. Ozturk, S. Sampath, R.
DeSilva, R. J. Aviles, M. Xu, V. J. Wright, W. H. Shenke, O.
Kocaturk, A. J. Dick, V. K. Raman, E. Atalar, E. R. McVeigh, R. J.
Lederman, Real-Time MRI-Guided Endovascular Recanalization of
Chronic Total Arterial Occlusion in a Swine Model, Circulation, 113:
1101 - 1107 2006.
-
Aravind Arepally, Parag V. Karmarkar, Clifford Weiss, Ergin Atalar,
“Percutaneous MR-Guided Transvascular Access of the Mesenteric
Venous System”, Radiology 238(1): 113-118 2006.
-
Susil
RC, Menard C, Krieger A, Coleman JA, Camphausen K, Choyke P,
Fichtinger G, Whitcomb LL, Coleman CN, Atalar E, Transrectal
Prosotate Biopsy and Fiducial Marker Placement in a Standard 1.5T
MRI Scanner, Urology 175(1):113-120, 2006.
-
Scott
L. Chowning, Robert C. Susil, Axel Krieger, Gabor Fichtinger, Louis
L. Whitcomb, Ergin Atalar,A Preliminary Analysis and Model of
Prostate Injection Distributions, The Prostate, 66:344-357, 2006.
-
A.
N. Raval, P. V. Karmarkar, M. A. Guttman, C. Ozturk, R. DeSilva, R.
J. Aviles, V. J. Wright, . H. Schenke, E. Atalar, E. R. McVeigh, R.
J. Lederman, Real-Time MRI Guided Atrial Septal Puncture and Balloon
Septostomy in Swine, Catheterization and Cardiovascular
Interventions, 67:637-643, 2006.
-
X.
Yang and E. Atalar, MRI-guided Gene Therapy, FEBS Letters, 580(12)
2958-2961 2006.
-
A. Arepally, P. V.
Karmarkar,
Di Qian, B. Barnett, E. Atalar, Evaluation of Three Types of MR-guided
Porto-Systemic Shunts, Journal of Vascular & Interventional
Radiology. 17(7):1165-1173, July 2006.
-
El-Sharkawy AM, M. Schar, P. A. Bottomley, Atalar, E. Monitoring and
correcting spatio-temporal variation of the MR scanner’s static
magnetic field.Thermal Status of Magnets Affects Proton-Resonance
Frequency Shift MR Thermometry, Magnetic Resonance Materials In
Physics, Biology And Medicine, 19:223-236, 2006.
-
El-Sharkawy,
Sotiriadis P. P., Bottomley P. A. and Atalar E. "In
Press Absolute Temperature Monitorung using RF Radiometry in the MRI
Scanner", IEEE Transactions on Circuits
and Systems, Vol 53, No: 11, November 2006.
-
S. Sathyanarayana, P. Aksit, A. Arepally, P. V. Karmarkar, M.
Solaiyappan, E. Atalar, Planar Orientations Of Active MRI Needles, J
Magnetic Resonance Imaging, 26(2):386-391, 2007.
-
I. B. Akca, O. Ferhanoglu, C. J. Yeung, S. Guney, T. O. Tasci, E.
Atalar, “Measuring Local RF Heating in MRI: Simulating Perfusion in
a Perfusionless Phantom”, Journal of Magnetic Resonance Imaging
26(5):1228-1235, 2007.
-
Chris Brushett, Bensheng Qiu, Ergin Atalar, and Xiaoming Yang
High-Resolution MRI of Deep-Seated Atherosclerotic Arteries Using
Motexafin Gadolinium, Journal of Magnetic Resonance Imaging J
27:246-250 (2007)
-
Memis G, Eryaman Y, Aytur O, Atalar E. Miniaturized Fiber Optic
Transmission System for Magnetic Resonance Imaging Signals, Magnetic
Resonance in Medicine, 59:165-173, 2008.
-
Haydar Celik, Aslı Uluturk, Turgut Tali, Ergin Atalar “A Catheter
Tracking Method Using Reverse Polarization for MR-guided
Interventions”, Magnetic Resonance in Medicine, 58:1224-1231, 2007.
-
T. Onur Tasci, Ergin Atalar, U. Korcan Demirok, and Sefik Suzer
“Electrical circuit modeling of surface structures for X-ray
photoelectron spectroscopic measurements”, Surface Science, 602.
365-368. 2008.
ABSTRACTS
- Eryaman Y, Celik H, Altintas A, Hafez IA, Atalar E, "Evaluation
of Internal Coils Using Ultimate Intrinsic SNR" (poster) 11th
Annual Meeting of ISMRM, Toronto, 2003.
- Eryaman Y, Celik H, Altintas A, Hafez IA, Atalar E, "Dahili
Bobinlerin En İyi İçsel Sinyal/Gürültü Oranı Kullanılarak
Değerlendirilmesi" (oral). URSI Bilkent 2004.
- Celik H, Eryaman Y, Altintas A, Erturk VB, Atalar E, "Microstrip
Based MR Birdcage Coil for 1.5 T" (poster). IMIM Istanbul 2005.
- Eryaman Y, Celik H, Altintas A, Atalar E, "Novel
Strip-Conductor Internal MRI Coils" (oral). APS-URSI Washington
2005.
- Celik H, Eryaman Y, Altintas A, Erturk VB, Atalar E, "Microstrip
Based MR Birdcage Coil for 1.5 T" (oral). APS-URSI Washington
2005.
- Celik H, Atalar E,
"A Novel Catheter
Tracking Method Using Reversed Polarization" (oral). ESMRMB
Basel 2005.
- Celik H, Ulutürk A, Eryaman Y, Talı T, Atalar E,
"A
Novel Catheter Tracking Method Using Reversed Polarization"
(oral). ISMRM Seattle 2006.
- Celik H, Quick HH, Atalar E, "Wireless
Active Catheter Tracking Method Using Reversed Polarization of
Phased Array Coils for MR-guided Interventions" (oral). IMRI
Leipzig 2006.
- Celik H, Quick HH,
Zenge MO, Atalar E,
"Wireless Active
Catheter Tracking Method Using Reversed Polarization: Implementation
of 12-Channels Phased Array Coil" (oral). ESMRMB Warsaw 2006.
- Celik H, Quick HH,
Zenge MO, Atalar E, "Implementation
of Wireless Active Catheter Tracking Method Using Reversed
Polarization to the Phased Array Coils" (oral). MRA Club Basel
2006.
PATENTS
-
Atalar, E. and E. R. McVeigh, A Method of Minimizing Dead-Periods
in Magnetic Resonance Imaging Pulse Sequences and Associated
Apparatus, Assignee: Johns Hopkins University: US Patent
5,512,825, Apr. 30, 1996.
-
Atalar, E., P.A. Bottomley, and E.A. Zerhouni, Method of Internal
Magnetic Resonance Imaging and Spectroscopic Analysis and Associated
Apparatus, Assignee: Johns Hopkins University: US Patent
5,699,801, Dec. 23, 1997. Also filed in Japan (HEI8-536670), Canada
(2222742), and EP (96917873).
-
Ocali, O. and E. Atalar, Method of Magnetic Resonance Imaging and
Spectroscopic Analysis and Associated Apparatus, 27 July 1999,
Assignee: Johns Hopkins University: US Patent, 05928145. Also filed
as PCT (US97/06444). Filed in Japan (HEI9-538187), Australia
(26748/97), Canada (2,252,431), Hong Kong, and EP (97918711.9).
World Intellectual Property Publication (WO 01/06925 A1, 1 Feb 2001)
-
Atalar, E. and O. Ocali, Method of Magnetic Resonance Analysis
Employing Cylindrical Coordinates and An Associated Apparatus,
February 29, 2000, Assignee: Johns Hopkins University: US Patent
6,031,375. Also a PCT application was filed 9824738.
-
Reeder, S. B., Atalar, E., Faranesh, McVeigh, E. R., Magnetic
Resonance Imaging Method and Apparatus and Method of Calibrating the
Same, Assignee: Johns Hopkins University: US Patent 6,188,219,
Feb 13, 2001.
-
Atalar, E., J. C. Lesho, H. K. Charles, B. G. Carkhuff, and P. A.
Bottomley, Miniature Magnetic Resonance Catheter Coils and
Related Methods, US Patent 6,263,229, Jul 17, 2001.
-
Atalar, E., and O. Ocali, Enhanced Safety Coaxial Cables, US
Patent 6,284,971, September 4, 2001.
-
J. A. C. Lima, K. A. Shunk, E. Atalar, Transesophageal Magnetic
Resonance Analysis Method and Apparatus, US Patent 6,408,202, Jun
18, 2002.
-
E. Atalar, P. Bottomley, E. Zerhouni, H. Halperin, E. McVeigh, A.
Lardo, Methods for In Vivo Magnetic Resonance Imaging, US
Patent 6,549,800, April 15,2003. International Publication Number
WO062672B1.
-
Atalar, E.. Bottomley, P.A., Karmarkar, P., Lardo, A. C., E. A.
Zerhouni, Apparatus, Systems and Methods for in Vivo Magnetic
Resonance Imaging, US Patent 6,628,980, September 30, 2003.
-
A. Lardo, X. Yang, E. Atalar, P. Karmarkar, E. McVeigh, H. Halperin,
C. McNamara, P. Bottomley, Magnetic Resonance Imaging Wire and
Guidewire, U.S. Patent 6,675,033, January 6, 2004.
-
H. Halperin, R. D. Berger, E. Atalar, E. R. McVeigh, A. Lardo, H.
Calkins, J. Lima, Magnetic-Resonance-Guided Imaging,
Electrophysiology, And Ablation, US Patent 6,701,176, March 2, 2004.
-
P. Aksit, A. Derbyshire, E. Atalar, System and Method of
Real-Time Multiple Field-Of-View Imaging, US Patent 6,778,689,
August 17, 2004.
-
E. Atalar, H. H. Quick, P. Karmarkar, Systems and
Methods for Evaluating the Urethra and the Periurethral Tissues,
US Patent 6,898,454, May 24, 2005 (Based on Application 09/824,536
filed April 2, 2001.)
-
V. Paliwal, A. M. El-Sharkawy, E. Atalar, Steady state free
precession based magnetic resonance thermometry, US Patent
7,078,903, July 18, 2006.
-
H. R. Halperin, R. D. Berger, E. Atalar, E. McVeigh, A. Lardo, H.
Calkins, J. Lima, System and Method for Magnetic-Resonance-Guided
Electrophysiologic and Ablation Procedures, US Patent 7,155,271, Dec
26, 2006.
-
A. Kumar, E. Atalar, O. Ocali, Biopsy and sampling needle antennas
for magnetic resonance imaging-guided biopsies, US Patent 7,236,816,
Jun 26, 2007 (Based on Application Filed on April 25, 2002.)
Published Patent Applications:
-
P. V. Karmarkar, E. Atalar, R. J. Lederman, A. N. Raval,
Interventional devices for chronic total occlusion recanalization
under MRI guidance, US Patent Application, US 2006/0106303
Publicaton date May 18, 2006.
-
H. R. Halperin, R. D. Berger, E. Atalar, E. R. McVeigh, A. Lardo, H.
Calkins, J. Lima, Brain Therapy, US Patent Application, US
2004/0167392, Publication Date: Aug 26, 2004.
-
E. Atalar, P. Bottomley, P. Karmarkar, A. Lardo, E. Zerhouni,
Apparatus, Systems And Methods For In Vivo Magnetic Resonance
Imaging, US Patent Application US 2002/0045816 A1, April 18,
2002.
-
X. Yang and E. Atalar, Imaging Nucleic Acid Delivery, US Patent
Application US 2002/0192688 A1, December 19, 2002 (Based on US
Provisional No: 60/281,589 filed on April 4, 2002.)
-
S. Tully, A. C. Lardo, R. Karmarkar, E. McVeigh, H. R. Halperin, C.
E. McNamara, P. A. Bottomley, E. Atalar, X. Yang, Magnetic Resonance
Imaging Probe, US Patent Application, US 2003/0028095 A1, February
6, 2003.
-
R. Susil, E. Atalar, A. C. Lardo, H. R. Halperin, R. D. Berger, H.
Calkins, P. Bottomley, Systems And Methods For
Magnetic-Resonance-Guided Interventional Procedures, US Patent
Application, US 2003/0050557 A1, March 13, 2003.
-
H. R. Halperin, R. D. Berger, E. Atalar, E. R. McVeigh, J. Lima, H.
Calkins, System and Method for Magnetic-Resonance-Guided
Electrophysiologic and Ablation Procedures. US Patent
Application, US 2003/0199755 A1, October 23, 2003. (Based on
Provisional US Patent Application, Serial No: 60/106,965 filed
November 4, 1998,. Also filed as 09/428990 and US PCT99/25858.)
-
X. Yang, E. Atalar, C. Yeung, Device, Systems and Methods for
Localized Heating of A Vessel and/or in Combination with MR/NMR
Imaging of the Vessel and Surrounding Tissue, US Patent Application,
US 2004/0024434 A1, February 5, 2004.
-
H. R. Halperin, R. D. Berger, E. Atalar, E. R. McVeigh, A. Lardo, H.
Calkins, J. Lima, US Patent Application, US 2004/0167392 A1, August
26, 2004.
-
P. V. Karmarkar, Active MRI Intramyocardial Injection Catheter With
A Deflectable Distal Section, US Patent Application, US2004/0220470
A1. Nov. 4, 2004.
-
E. Atalar, R. Susil, MRI Compatible Medical Leads, US Patent
Application US 2007/0088416 A1, April 19, 2007
-
E. Atalar, O. Ferhanoglu, Electrical lead for an electronic
device such as an implantable device, US Patent Application US
2006/0252314 A1, November 9, 2006
-
G. Fichtinger, E. Atalar, L. L. Whitcomb, R. C. Susil, A. Tanacs, A.
Krieger, Apparatus
for insertion of a medical device during a medical imaging process,
US Patent
Application US 2006/0241368 A1, October 26, 2006.
-
E. Atalar,H.H. Quick, P.
Karmarkar, Evaluating the urethra and the periurethral Tissues,
US Patent Application US 2006/0122493 A1, June 8, 2006
-
H. R. Halperin, R. D. Berger, E. Atalar, E. R. McVeigh, A. Lardo, H.
Calkins, J. Lima, System and method for magnetic-resonance-guided
electrophysiologic and ablation procedures, US Patent
Application US 2006/0100506 A1, May 11, 2006
-
V. Paliwal, A. El-Sharkawy, E. Atalar, Steady state free
precession based magnetic resonance thermometry, US Patent
Application US 2005/0052183 A1, March 10, 2005
-
A. Kumar, E. Atalar, O. Ocali, Biopsy and sampling needle
antennas for magnetic resonance imaging-guided biopsies, US
Patent Application US 20030028094 A1 Febuary 6, 2003
-
E. Atalar, P. A. Bottomley, P. Karmarkar, A. C. Lardo, E. Zerhouni,
Apparatus, systems, and methods for in vivo magnetic resonance
imaging, US Patent Application US 2002/0045816 A1, April 18,
2002.
|
 |
|